• Skip to main content
  • Skip to footer
CAEN logo light
  • About
    • Company Profile
    • Our policy
    • Sales network
    • Innovative Projects
    • Careers
    • How to reach us
  • Products
  • Resources
    • Documentation
    • FAQ
    • Glossary
    • Certifications
    • General Conditions
    • CAEN LHC Commitment
  • Support
  • Contact
Form FactorPower SupplyDigital SpectroscopyModular Pulse ProcessingEducationalFirmware & SoftwarePowered CratesAccessoriesWeeroc ProductsDigitizer FamiliessubfamilyWithoutFamily

Easypet Kit

SP5701

Home EducationalNuclear and Particle Physics ExperimentsPhotons SP5701

CAEN realized different modular Educational Kits. The set-up are based on a portable Digital MCA for Gamma spectroscopy and a Silicon Photomultipliers (SiPM) state of-the-art sensor of light with single photon sensitivity and unprecedented photon number capability. The goal is to inspire students and guide them towards the analysis and comprehension of different physics phenomena with a series of experiments based on state-of-the art technologies, instruments and methods.

What’s inside

  • EasyPET is a simple, user friendly and portable didactic PET system developed for high-level education, which allows exploring the physical and technological principles of the conventional human PET scanners, using the same basic detectors of state-of- the-art systems. The Positron Emission Tomography (PET) scanner is the state-of-the-art medical imaging system, capable of providing detailed functional information of physiological processes inside the human body. Functional imaging has a great impact in cancer diagnostics, monitoring of therapy effects and cancer drug development. The underlying principle to PET systems is the detection of high energy radiation emitted from a chemical marker, a molecule labelled with a radioisotope, administered to a patient. The radioisotope emits positrons which, after annihilating with atomic electrons, result in the isotropic emission of two photons back to back with an energy of 511 keV. The two photons are detected by a ring of detectors, which allows a pair of them to detect two back to back photons in any direction.

  • The DT5770 is a compact portable Digital MCA for Gamma spectroscopy. It is suited for high energy resolution semiconductor detectors, like HPGe and Silicon Drift Detector, connected to a Charge Sensitive Preamplifier. The unit can also properly operate directly connected to a PMT with inorganic scintillators (e.g. Nal or Csl scintillators), provided exponential pulse shape and decay time above 200 ns. It integrates analog front-end with programmable gain and possible AC coupling.

Easy PET Control Software

EasyPET is controlled through a Graphic User Interface (GUI), developed in Visual Basic, which allows setting the acquisition parameters, performing the acquisition, visualizing the reconstructed image in real time during acquisition and recording the data for the offline analysis, performing calibration and spatial resolution measurements.


Features

  • Gamma Spectroscopy and System Linearity

  • Positron Annihilation Detection

  • Nuclear Imaging

  • Two-dimensional Reconstruction of a Radioactive Source

  • Source Spatial Resolution

  • Efficiency measurements

  • User Friendly Control SW with Graphical User Interface


Ordering Options

Code Description
WK5701XAAAAA

SP5701 EasyPET Kit

 

(In production)

RoHS
Data Sheet Manual Download Compare

SP5701: Data Sheets

Name
Revision
Format
File Size
Last Update
SP5701 - Parts List
0
pdf
0.18 Mb
13/05/2021

SP5701: Manuals

Name
Revision
Format
File Size
Last Update
DT5770 - Digital MCA
2
pdf
3.33 Mb
09/05/2017

SP5701: Download

Guides

Name
Revision
Format
File Size
Last Update
SP5701 - EasyPet Kit
2
pdf
3.24 Mb
19/06/2018

Experiments

Name
Revision
Format
File Size
Last Update
SG6131 - Basic Measurements: Gamma Spectroscopy and System Linearity
0
pdf
0.94 Mb
07/06/2017
SG6132 - Positron Annihilation Detection
0
pdf
0.92 Mb
07/06/2017
SG6133 - Two-dimensional Reconstruction of a Radioactive Source
0
pdf
0.8 Mb
07/06/2017
SG6134 - Spatial Resolution
0
pdf
0.94 Mb
07/06/2017

Driver

Name
Revision
Format
File Size
Last Update
OS
DT5770-XX495 mini-USB Driver
2.12.28
zip
2.34 Mb
07/05/2021
Windows

Applications SW

Name
Revision
Format
File Size
Last Update
OS
CAEN DT5770 Upgrader
1.3
zip
0.39 Mb
01/09/2017
Windows
EasyPET Control Software
1.2.3.6
zip
79.75 Mb
10/10/2017
Windows
Name
Revision
Format
File Size
Last Update
DT5770 Firmware
5
NIU
1.69 Mb
22/11/2017

Add to Wishlist
This product is already in your Wishlist
Browse the Wishlist

Request a Quote

Request a Quote

    Submit I’ve read and accept the privacy policy *

    Footer

    CAEN S.p.A.

    PI 00864500467 | REA: LU 102690

    C.I.V.: 500.000€ | CDU A47Ø7H7

    Caen Group Logo
    Certificate ISO 9001:2015
    Secured by Sectigo

    About Us

    • Company Profile
    • Our policy
    • Sales network
    • Innovative Projects
    • Careers
    • How to reach us

    Products

    Applications

    • High Energy Physics
    • Astrophysics
    • Neutrino Physics
    • Dark Matter Investigation
    • Nuclear Physics
    • Material Science
    • Medical Applications
    • Homeland Security

    Resources

    • Resources

    Support

    • Getting Started with MyCAEN Portal

    News

    • News

    Contact Us

    • Contact

    Login

        
    • Privacy Policy
    • Cookie Policy

    Copyright © 2024 CAEN S.p.A. All rights reserved. Website by Addiction

    ✕