12 Channel 3 kV/3mA, 4 kV/2 mA, 4 kV/0.2 mA

A1833

Home Power SupplyUniversal Multichannel SystemA7030 - A7236 - A7435 A1833

The Mod. A1833 is a single width board housing 12 HV channels with either positive (A1833P) or negative (A1833N) polarity.

The Mod. A1833 output channels offer 3 kV / 3 mA or 4 kV / 2 mA or 4 kV / 200 µA full scale range (dip-switch selectable).

If the output voltage differs from the programmed value by more than 3% of voltage full scale range, the channel is signalled to be either in OVERVOLTAGE or UNDERVOLTAGE condition. Moreover, for each channel, a voltage protection limit SVMAX can be fixed via software with 1 V resolution and the output voltage can not be programmed beyond this value.

The HV RAMP-UP and RAMP-DOWN rates may be selected independently for each channel in the range 1÷500 V/s in 1 V/s steps.

The output current is monitored with 20 nA / 200 nA resolution depending on current range; if a channel tries to draw a current larger than its programmed limit it is signalled to be in OVERCURRENT condition; the SY1527 system detects this state as a fault and reacts according to the setting of the TRIP parameter, namely:

1)TRIP=infinite ( = 1000 s)

The output current is permitted to exceed the programmed limit; if the maximum output current value is reached the channel behaves like a constant current generator.

2)TRIP=finite (< 1000 s)

The output current is permitted to exceed the limit only for programmed time interval and then is switched off.

The TRIP time (i.e. the maximum time an OVERCURRENT condition is allowed to last) can be programmed in 0.1 s steps.

The maximum output voltage (VMAX Hardware) can be fixed, through a potentiometer located on the front panel, at the same common value for all the board channels and this value can be read out via software.

The boards are provided with an “HV EN” input that disables the channels when it is not connected to ground.


Features

  • 12 channel HV boards
  • Dual range (0÷4 kV/0÷3 kV) output voltage
  • Dual current range (2 / 0.2 mA) for 4 kV mode
  • Available with positive or negative polarity
  • 0.25 Volt Voltage Set / Monitor resolution
  • 20 nA / 200 nA (low / high range) current Set / Monitor resolution
  • Voltage ripple smaller than 30 mV pp
  • Programmable TRIP parameter
  • 1÷500 Volt /sec programmable Ramp Up/Down
  • Current generator operation in Overcurrent condition

Ordering Options

Code Description
WA1833NAAAAA

A1833N – SYx527 H.V. channels -3/4 KV 3/2 mA/200µA – SHV Conn. (12 ch)

 

(Obsolete)

WA1833PAAAAA

A1833P – SYx527 H.V. channels +3/4 KV 3/2 mA/200µA – SHV Conn. (12 ch)

 

(Obsolete)

Manual Compare

A1833: Manuals

Name
Revision
Format
File Size
Last Update
A1833/A1833B-A1733/A1733B - 12/28 Channels 3 kV/3 mA, 4 kV/2 mA, 4 kV/0.2 mA Common Ground Dual Range Boards
10
pdf
1 Mb
03/09/2013

Add to Wishlist
This product is already in your Wishlist
Browse the Wishlist

Request a Quote

Request a Quote

    Submit I’ve read and accept the privacy policy *

    Footer

    CAEN S.p.A.

    PI 00864500467 | REA: LU 102690

    C.I.V.: 500.000€ | CDU A47Ø7H7

    Caen Group Logo
    Certificate ISO 9001:2015
    Secured by Sectigo

    About Us

    • Company Profile
    • Our policy
    • Sales network
    • Innovative Projects
    • Careers
    • How to reach us

    Products

    Applications

    • High Energy Physics
    • Astrophysics
    • Neutrino Physics
    • Dark Matter Investigation
    • Nuclear Physics
    • Material Science
    • Medical Applications
    • Homeland Security

    Resources

    • Resources

    Support

    • Getting Started with MyCAEN Portal

    News

    • News

    Contact Us

    • Contact

    Login

        
    • Privacy Policy
    • Cookie Policy

    Copyright © 2024 CAEN S.p.A. All rights reserved. Website by Addiction

    ✕